DSpace Repository

Population-adjusted cut-off: A new approach for enhancing the diagnostic efficacy of hematological discrimination formulae for screening β-Thalassemia trait

Show simple item record

dc.contributor.author Karunaithas, R.
dc.contributor.author Aravinda, I.
dc.contributor.author Dharmasiri, S.
dc.contributor.author Sewwandi, C.
dc.contributor.author Karunaithas, S.
dc.contributor.author Goonetilleke, S.
dc.date.accessioned 2026-09-01T02:27:59Z
dc.date.available 2026-09-01T02:27:59Z
dc.date.issued 2026
dc.identifier.citation Aravinda, I., Dharmasiri, S., Sewwandi, C., Karunaithas, S., Goonetilleke, S., & Rasaratnam, K. (2026). Population-adjusted cut-off: A new approach for enhancing the diagnostic efficacy of hematological discrimination formulae for screening β-thalassemia trait. Clinica Chimica Acta, 579, 120592. en_US
dc.identifier.uri http://repo.lib.jfn.ac.lk/ujrr/handle/123456789/12950
dc.description.abstract Screening for β-thalassemia trait (βTT) is crucial for preventing β-thalassemia major in offspring. Although hematological discrimination formulae (HDF), developed using complete blood count parameters, are cost-effective tools for screening βTT, their performance varies across different populations. This study evaluated the performance of 32 HDF for screening βTT in the Sri Lankan population. Data were retrieved from laboratory databases and categorized into confirmed βTT and non-βTT groups based on high-performance liquid chromatography results. The βTT screening performance of the HDF was assessed using accuracy measurements, the receiver operating characteristic (ROC) curve, and Youden’s index (YI). Furthermore, a population-adjusted cut-off was determined using the Index of Union (IU) method to optimize the predictive accuracy of HDF in screening βTT. Bordbar demonstrated excellent predictive performance in males (AUC = 0.908; YI = 0.815), while Shine & Lal, Kerman-I, Nishad, Sehgal, Bordbar, and Roth demonstrated high discriminative ability in females (AUC > 0.833; YI > 0.666). Applying a population-adjusted cut-off improved the βTT screening potential of Shine & Lal, Kerman-I, Nishad, Bordbar, and Roth in males (AUC > 0.911; YI > 0.822) and enhanced the performance of Kerman-II in females (AUC > 0.861; YI > 0.722). Notably, Shine & Lal (AUC = 0.937; YI > 0.873) and Nishad (AUC = 0.897; YI > 0.794) demonstrated the best performance for males and females, respectively, when a population-adjusted cut-off was applied for screening βTT. In conclusion, determining a population-adjusted cut-off is a new initiative to enhance the βTT screening performance of HDF across different populations. en_US
dc.language.iso en en_US
dc.publisher Elsevier en_US
dc.subject β-thalassemia trait en_US
dc.subject Population-adjusted cut-off en_US
dc.subject Hematological discrimination formulae en_US
dc.subject Sri Lanka en_US
dc.title Population-adjusted cut-off: A new approach for enhancing the diagnostic efficacy of hematological discrimination formulae for screening β-Thalassemia trait en_US
dc.type Journal abstract en_US
dc.identifier.doi https://doi.org/10.1016/j.cca.2025.120592 en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record