DSpace Repository

Optimization of total RNA extraction from human urinary sediment

Show simple item record

dc.contributor.author Saseevan, S.
dc.contributor.author Magana-Arachchi, D.N.
dc.contributor.author Rajapakse, S.
dc.date.accessioned 2025-04-03T05:45:13Z
dc.date.available 2025-04-03T05:45:13Z
dc.date.issued 2021
dc.identifier.uri http://repo.lib.jfn.ac.lk/ujrr/handle/123456789/11194
dc.description.abstract Urine is the best choice to identify biomarkers for metabolic and renal disorders because it is readily available, and samples can be obtained non-invasively from patients. However, RNA isolation from voided urine is challenging due to the presence of RNases and cell scarcity. This study aims to optimize a protocol for RNA extraction from urine samples in gene expression studies. Twenty urine samples were collected from healthy controls (HC) (n = 11; 49 ± 5 years) and chronic kidney disease (CKD) patients (n = 9; 62 ± 3 years) and were centrifuged at 3,000 g for 30 min at 4 °C. Then, 500 μL of the lysis buffer was added to the pellet, vortexed and kept on ice for 5 min. Next, 100 μL of sodium acetate (pH = 4.0) and 500 μL of water-saturated phenol were added and mixed well. After that, 200 μL of chloroform: isoamyl alcohol (49:1) was added, vortexed and centrifuged. An equal volume of cold isopropanol was added to the aqueous phase and incubated at -20 °C for 1 h to precipitate RNA. The pellet was washed with 75% ethanol, air dried, and resuspended with 12 μL nuclease-free water. Finally, the RNA was quantified and reverse transcribed into cDNA to be used in RT-qPCR. Mean urine volume was 82.5 ± 41.9 mL. Serum creatinine and estimated glomerular filtration rate of CKD patients were 3.0 ± 0.2 mg dL-1 and 19.2 ± 4.8 mL min-1 1.73 m-2, respectively. The total yield of RNA from CKD and HC samples were 873 ± 523 ng and 735 ± 291 ng, respectively, and a statistically significant difference was not observed between the two study groups (p > 0.05). The β2 microglobulin gene could be successfully amplified using samples even with a low cDNA concentration (0.625 ng). This modified phenol-chloroform based urinary RNA isolation method is less expensive, does not require RNA clean-up kits and provides a higher yield of RNA with less inhibition which is sufficient for downstream applications than column-based techniques. en_US
dc.language.iso en en_US
dc.publisher Postgraduate Institute of Science Research Congress, Sri Lanka en_US
dc.subject Chronic kidney disease en_US
dc.subject RNA isolation en_US
dc.subject Urinary sediment en_US
dc.title Optimization of total RNA extraction from human urinary sediment en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record