DSpace Repository

Effect of Roof and Diaphragm Connectivity on Dynamic Behaviour of the PP-band Retrofitted Adobe Masonry Structures

Show simple item record

dc.contributor.author Sathiparan, N.
dc.date.accessioned 2021-03-08T04:38:57Z
dc.date.accessioned 2022-06-27T09:46:42Z
dc.date.available 2021-03-08T04:38:57Z
dc.date.available 2022-06-27T09:46:42Z
dc.date.issued 2018
dc.identifier.citation Sathiparan, N. (2018). Effect of roof and diaphragm connectivity on dynamic behaviour of the PP-band retrofitted adobe masonry structures. Periodica Polytechnica Civil Engineering, 62(4), 992-1000. en_US
dc.identifier.uri http://repo.lib.jfn.ac.lk/ujrr/handle/123456789/1786
dc.description.abstract This paper discusses the shaking table test results of three PP-band (Polypropylene band) retrofitted quarter scale one-story masonry house models with different roof conditions. Better connections between masonry wall and roof connection are one factor to improve the seismic safety of the masonry houses. Past studies show that PP-band retrofitting improves the integrity of structural components and prevent the collapse of masonry structures during an earthquake. Although the effect of masonry unit type, surface plastering, the pitch of the PP-band mesh, PP-band connectivity in mesh and tightness of the mesh attachment to walls were studied by experiment program, the effect of the roof and its diaphragm connectivity on PP-band retrofitted masonry structure is nonexistent. Therefore, an experimental program was designed and executed for an understanding the effect of the roof and its connection on the dynamic behavior of the PP-band retrofitted box-shaped masonry house models. Results reveal that the PP-band retrofitted models with proper roof diaphragm improves the seismic behavior with respect to lateral drift, shear resistance and ductility. en_US
dc.language.iso en en_US
dc.subject PP-band retrofitting en_US
dc.subject adobe masonry en_US
dc.title Effect of Roof and Diaphragm Connectivity on Dynamic Behaviour of the PP-band Retrofitted Adobe Masonry Structures en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record