DSpace Repository

Dynamic behavior of timber roof Masonry house models Retrofitted by pp-band meshes

Show simple item record

dc.contributor.author Sathiparan, N.
dc.contributor.author Mayorca, P.
dc.contributor.author Meguro, K.
dc.date.accessioned 2021-03-02T07:48:27Z
dc.date.accessioned 2022-06-27T09:47:15Z
dc.date.available 2021-03-02T07:48:27Z
dc.date.available 2022-06-27T09:47:15Z
dc.date.issued 2009
dc.identifier.uri http://repo.lib.jfn.ac.lk/ujrr/handle/123456789/1736
dc.description.abstract Unreinforced masonry is one of the most popular construction materials in the world. It is also unfortunately, the most vulnerable against earthquakes. Damage to unreinforced masonry buildings has caused huge number of human casualties historically and during recent earthquakes in developing countries. Therefore, retrofitting of low earthquake-resistant masonry structures is the key issue for earthquake disaster mitigation in developing countries to reduce the casualties significantly. When we propose the retrofitting in developing countries, retrofitting method should respond to the structural demand on strength and/or deformability as well as to availability of material with low cost including manufacturing and delivery, practicability of construction method and durability in each region. Considering these issues of developing appropriate seismic retrofitting techniques for masonry buildings to reduce the possible number of casualties due to future earthquakes in developing countries, a technically feasible and economically affordable PP-band (polypropylene bands) retrofitting technique has been developed and many different aspects have been studied by Meguro Laboratory, Institute of Industrial Science, The University of Tokyo. PP-band is commonly used for packing. In order to understand the dynamic response of masonry houses with and without PP-band mesh retrofitting, crack patterns, failure behavior, and overall effectiveness of the retrofitting technique, shaking table tests were carried out. In this experimental program, ¼ scale single box shape room structure with wooden roof models were used. Addition to that, effect of surface plaster on PP-band retrofitted house model also studied. From the experimental results, it was found that a scaled dwelling model with PP-band mesh retrofitting was able to withstand larger and more repeatable shaking than that without PP band retrofitting, which all verified to reconfirm high earthquake resistant performance. When surface finishing applied above house model, due to improve bond connection between PP-band and brick wall, surface plaster kept well with wall. en_US
dc.language.iso en en_US
dc.subject unreinforced masonry en_US
dc.subject polypropylene band en_US
dc.title Dynamic behavior of timber roof Masonry house models Retrofitted by pp-band meshes en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record