Cold-formed steel sections are used in many different shapes based on their applications. Recently, a new Csection
known as SupaCee was introduced in Australia with higher flexural capacities compared to traditional
channel sections. However, all cold-formed steel sections are vulnerable to web crippling failures due to their
higher plate slenderness. Australian/New Zealand (AS/NZS 4600) and North American (AISI S100) Standards
use a unified web crippling design equation with four coefficients while Eurocode 3 Part 1.3 uses different design
equations to predict the web crippling capacities of cold-formed steel sections. The web crippling coefficients
were developed based on the experimental studies undertaken since the 1940s. These experimental studies
utilised different test set-ups and specimens lengths and hence the accuracy of predictions using these coefficients
may be inadequate. No coefficients are available for unlipped channel sections with fastened supports and
high strength SupaCee sections while the same coefficients are used for lipped channels with fastened and
unfastened supports. To address these shortcomings, the web crippling behaviour of unlipped and lipped channel
and SupaCee sections was experimentally investigated based on recently developed AISI S909 web crippling test
guidelines. Finite element analyses were then performed to extend the range of cold-formed steel sections. Using
the web crippling capacity results from both experiments and finite element analyses, new equations were
proposed to determine the web crippling capacities of lipped and unlipped channel and SupaCee sections.
Suitable direct strength method based web crippling design equations were also developed. This paper presents
the important details of several detailed web crippling studies undertaken recently including a suite of web
crippling design equations that can be adopted in relevant cold-formed steel standards.