Title: Performance evaluation of submerged membrane bioreactor for the removal of microalgae from the source water of a water treatment plant
Authors: Thiruchchelvam, Thinojah
Kalahara, Walimuni Dissanayakage Lakshitha Manula
Abeykoon, Yatikindage Malith Dilshan
Balachandran, Ketheesan
Keywords: Air scouring;Algae fouling;Backwashing;Flat sheet membrane;Vibration;Energy consumption
Issue Date: 2023
Publisher: Elsevier
Abstract: Freshwater algal blooms negatively impact the operations of water treatment plants when they are present in the source water. In the present study, an application of a low-cost submerged microfiltration membrane bioreactor for the removal of microalgae from a source water reservoir of a water treatment plant was evaluated. The experiments were conducted in different phases to systematically evaluate how different fouling control methods such as air scouring and water backwashing in combination with vibration technique can enhance the flux and removal efficiency of microalgae in a submerged flat sheet microfiltration membrane bioreactor. Combining backwashing with air scouring (Phase 3) positively enhanced the flux by reducing the TMP, but it did not improve the permeate quality in terms of microalgae and turbidity removal. The results of Phase 4 studies confirmed that vibration had a profound effect on microalgae removal compared to backwashing technique while reducing the TMP from 105 to 103 kPa. The average turbidity removal was increased from 76.75% to 82% when vibration is applied. Combining all fouling control methods such as air scouring, backwashing and vibration methods did not appear to be effective for the removal of microalgae and turbidity (Phase 5). In order to signify the energy input on membrane fouling control, flux in each phase was assessed with respect to total power input. In overall, air scouring at a rate of 7 L/min with 50 Hz of vibration appeared to be an optimum condition in controlling fouling without any frequent backwashing.
URI: http://repo.lib.jfn.ac.lk/ujrr/handle/123456789/9954
DOI: https://doi.org/10.1016/j.jece.2023.111200
Appears in Collections:Civil Engineering

Files in This Item:
File Description SizeFormat 
paper 3_2023.pdf888.95 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.