Please use this identifier to cite or link to this item: http://repo.lib.jfn.ac.lk/ujrr/handle/123456789/1395
Title: Bearing capacity of cold-formed unlipped channels with restrained flanges under EOF and IOF load cases
Authors: Janarthanan, B.
Mahendran, M.
Gunalan, S.
Keywords: Cold‐formed unlipped channel sections;bearing capacity
Issue Date: 2015
Publisher: Ernst & Sohn Verlag für Architektur und technische Wissenschaften GmbH & Co. KG, Berlin
Citation: Janarthanan, B., Mahendran, M., & Gunalan, S. (2015). Bearing capacity of cold‐formed unlipped channels with restrained flanges under EOF and IOF load cases. Steel Construction, 8(3), 146-154.
Abstract: Bearing failure is a form of localized failure that occurs when thin-walled cold-formed steel sections are subjected to concentrated loads or support reactions. To determine the bearing capacity of cold-formed channel sections, a unified design equation with different bearing coefficients is given in the current North American specification AISI S100 and the Australian/New Zealand standard AS/NZS 4600. However, coefficients are not available for unlipped channel sections that are normally fastened to supports through their flanges. Eurocode 3 Part 1.3 includes bearing capacity equations for different load cases, but does not distinguish between fastened and unfastened support conditions. Therefore, an experimental study was conducted to determine the bearing capacities of these sections as used in floor systems. Twenty-eight web bearing tests on unlipped channel sections with restrained flanges were conducted under End One Flange (EOF) and Interior One Flange (IOF) load cases. Using the results from this study, a new equation was proposed within the AISI S100 and AS/NZS 4600 guidelines to determine the bearing capacities of cold-formed unlipped channels with flanges fastened to supports. A new design rule was also proposed based on the direct strength method.
URI: http://repo.lib.jfn.ac.lk/ujrr/handle/123456789/1395
Appears in Collections:Civil Engineering

Files in This Item:
File Description SizeFormat 
Bearing capacity of cold-formed unlipped channels.pdf95.21 kBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.